Thermal Imaging & Solar Audits

Heat is where the fault shows first

Almost everything that is about to fail gets warm first. A cracked solar cell, a loose busbar, a bearing running dry, water tracking under a roof membrane – all of them announce themselves thermally weeks or months before anything is visible.

A radiometric thermal camera on a drone reads that heat across an entire asset in a single pass, which is the difference between checking a sample and checking everything.

Solar: the numbers that matter

A 100 MW park in Rajasthan has roughly 200,000 modules. A hand-held thermal audit samples maybe 2% of them and takes a fortnight. A drone audit reads 100% in two days.

What comes back is a module-level map: hotspots, bypass-diode failures, PID-affected strings, junction-box faults, soiling patterns and complete string outages, each pinned to a table and row number your site team can walk to.

In our experience on Indian parks, between 0.4% and 1.8% of modules on a two-year-old installation are underperforming enough to be worth rectifying. On a 100 MW asset the recovered generation from fixing them typically pays for the audit several times over in the first year – which is the argument that gets these programmes approved.

What you get

Radiometric, not colourised video

Every pixel carries a real temperature value, so findings are measured in degrees rather than eyeballed from a false-colour image.

Module-level solar reporting

Faults pinned to table, row and module position, classified by IEC 62446-3 anomaly type and ranked by generation impact.

Substation and switchyard scans

Hot joints, unbalanced phases and failing bushings identified from a safe standoff with the yard live.

Building envelope surveys

Water ingress paths, missing insulation and thermal bridging mapped across a roof or facade in one flight.

ASNT Level II interpretation

Data is read by a certified thermographer, not auto-tagged by software. Reflections and solar loading get ruled out before a finding is raised.

Pre-monsoon and annual cycles

Scheduled audits timed to the Indian maintenance calendar, with year-on-year trend comparison per string.

Deliverables

  • Module-level thermal orthomosaic
  • Defect table pinned to table / row / module ID
  • IEC 62446-3 anomaly classification
  • Estimated generation loss per defect class
  • Radiometric source files (R-JPEG)
  • Prioritised rectification schedule
How it runs

From enquiry to handover

01

Timing

Solar scans are flown between 11:00 and 14:00 at above 600 W/m² irradiance – outside that window the data is not diagnostic and we will not fly it.

02

Baseline

We take module datasheets and the SCADA string map first, so findings can be reported in your naming convention.

03

Flight

Automated grid at fixed altitude for consistent GSD, radiometric capture throughout.

04

Analysis

Certified thermographer reviews every anomaly, rules out reflections, and ranks by generation impact.

Indicative pricing

What it costs

Prices below are indicative for a standard scope in our four base cities and exclude GST. Every project gets a written fixed-price scope before we mobilise - no hourly surprises.

Rooftop / Small Plant

₹38,000 up to 1 MW
  • Full radiometric scan
  • Module-level defect table
  • Generation loss estimate
  • 5 working day report
Get a quote

Plant & Substation

₹95,000 per site day
  • Switchyard and plant thermal
  • ASNT Level II report
  • Severity-ranked defect register
  • Comparison with previous cycle
Get a quote

Thermal Imaging in the field

Thermal Imaging in the field
Thermal Imaging in the field
Thermal Imaging in the field
Questions we actually get asked

Thermal Imaging FAQs

No. Thermal solar work needs clear-sky irradiance above 600 W/m², so June to September is largely out across most of India. We schedule audits for October–May and say so at enquiry rather than taking a booking we cannot honour.

We do not do rectification – that keeps the audit independent. We hand a prioritised list to your O&M contractor and are happy to re-fly afterwards to verify the fix.

At our standard 3 cm thermal GSD we resolve single-cell hotspots reliably. Sub-cell defects need an IV-curve trace or EL imaging on the ground, which is a different service.

Ready to get your project in the air?

Tell us the site, the deliverable and the deadline. We will come back with a written scope, a clearance timeline and a fixed price - usually within one working day.

Udrone
Our Services
Contact Us
Mon – Sat 09.00 – 19.00 IST
4th Floor, Sky Vista Tech Park, Kadubeesanahalli, Outer Ring Road, Bengaluru – 560103, Karnataka, India
About Us

Udrone is a DGCA-compliant aerial services company flying survey, inspection and cinematography missions across India. Our certified remote pilots deliver survey-grade maps, 3D models, thermal audits and broadcast-quality film from Bengaluru, Mumbai, Delhi NCR and Hyderabad.

Call WhatsApp Enquire